Product Description

User-defined thermal resistance B/R/S/N/K/J/T/E thermocouple/thermopile
Number of input channels: 2
Main function: sensor matching, to achieve ultra-high precision measurement.
Max-Min, Average, Max-Min display.
Overlimit alarm.
C/F/K/Ω/mv measurement unit switching.
Data storage how much 390000 pen, including time information.
USB data directly connected to the computer.
Power supply: 6 ~ 15VDC external power supply or 4 AAA batteries.
Communication rate: 1200/2400/4800/9600/19200/38400bps
Uses:(1) precision detection of resistance, platinum resistance temperature corresponding resistance detection to save the consumption of second-class standard thermometer.
(2) Acceptance of thermostatic box temperature field.
(3.1) One channel is connected to a thermometer (second-class standard or JWPt100 thermometer), and the other channel is connected to the measured platinum resistance.
(3.2) One channel is connected to a second-class standard thermometer, and the other channel is connected to a JWPt100 thermometer for comparison and verification of the JWPt100 thermometer or to re-develop a JWPt100 indexing truth table based on the measurement data.
Resistance measurement accuracy (AT 25 ℃):

Range

Sampling mode

Resolution (typical) Ω

Error (max) Ω

300Ω

Ω

0.0001

±(0.0005 + 0.0006%*READ)

TRUEO

3kΩ

Ω

0.006

±(0.01 + 0.005%*READ)

TRUEO

DC voltage measurement accuracy (AT 25 ℃):

Range mV

Resolution (typical) uV

Error (max) uV

70

0.1

±(1 + 0.004%*READ)

 Resistance measurement accuracy (AT 25 ℃): temperature drift

Project

Impact per 1 ℃ of environmental change (maximum)

Resistance

2ppm*READ

Voltage

7ppm*READ

Resistance measurement accuracy (AT 25 ℃): electrical performance
The parameter conditions given in this table are: ambient temperature 25 ℃, power supply voltage 6V, dual-channel resistor sampling, and range 300 Ω.

Project

Condition

Typical value

Working current

Backlight on

13.5mA

Turn off backlight

11mA

Resistance measurement sampling time

Step change> 3mΩ, two channels simultaneously measure resistance

High resolution

Low resolution

6s

2s

Step change <3mΩ, two-channel simultaneous measurement of resistance

High resolution

Low resolution

18s

6s

Voltage measurement sampling time

two-channel simultaneous measurement of mv

0.5s

Thermocouple measurement sampling time

Simultaneous measurement of thermocouple signals with two channels

High resolution

Low resolution

6.5s

2.5s

 Resistance measurement accuracy (AT 25 ℃): the overall accuracy after matching with the sensor

Enter model number

Range (℃)

Accuracy (℃)

PT100

0~650

<±0.01

PT50

0~650

<±0.03

T-type thermocouple

-200~-50
-50~-300

<±0.3
<±0.15

N-type thermocouple

0~400
300~600

<±0.3
<±0.5

S-type thermocouple

0~600
600~1100

<±0.5
<±1.5