Product Description

Input type: 2/3/4 wire PT100/PT1000 and tungsten rhenium/B/R/S/N/K/J/T/E type thermocouple
Output mode: two-wire 4 ~ 20mA current loop
Output resolution: 1μA
Data update rate: 2 seconds-thermocouple 1 second -2/4 wire thermal resistance 1.5 seconds -3 wire thermal resistance
Thermocouple cold junction compensation accuracy (AT 25 ℃):(max) ± 0.05 ℃
Operating environment:-35~85 ℃ 0 ~ 95% relative humidity
Special function: can be matched with the sensor, to achieve ultra-high precision measurement.
When the thermocouple is input, the temperature compensation element can be externally connected to realize instant compensation.
Electrical isolation: non-isolated
Power supply: 6 ~ 36VDC
Accuracy (AT 25 ℃ maximum):

Enter model number

Range (℃)

A/D conversion accuracy

D/A conversion accuracy

Influence of 1 ℃ of environment change (temperature drift)

PT100

-200~500

±0.05℃

± 0.075% of range

0.003 ℃

Type B thermocouple

300~1820

± 1.40 ℃

± 0.075% of range

0.050 ℃

S-type thermocouple

0~1768

± 0.65 ℃

± 0.075% of range

0.040 ℃

N-type thermocouple

-200~1300

± 0.35 ℃

± 0.075% of range

0.035 ℃

K-type thermocouple

-180~1372

± 0.25 ℃

± 0.075% of range

0.034 ℃

J-type thermocouple

-180~760

± 0.20 ℃

± 0.075% of range

0.011 ℃

T-type thermocouple

-200~400

± 0.20 ℃

± 0.075% of range

0.015 ℃

Type E thermocouple

-50~1000

± 0.17 ℃

± 0.075% of range

0.009 ℃

digital/analog conversion

 

 

 

0.0025% Span

Note 1: Total digital accuracy of thermocouple measurement: analog/digital conversion accuracy 0.05 ℃ (cold end compensation accuracy)
Note 2: Total accuracy of the transmitter: analog-to-digital conversion accuracy, digital-to-analog conversion accuracy, please refer to the previous "about accuracy" for calculation method"
Overall accuracy after using sensor matching function (transmitter sensor)

Enter model number

Range (℃)

Accuracy of analog/digital conversion (℃)

PT100

-50~200

±0.05

S-type thermocouple

0~650

±0.70

650~1100

±1.50

N-type thermocouple

0~650

±0.40

650~1100

±1.90

T-type thermocouple

-200~-70

±0.40

-70~400

±0.20

Note 1: The sensors listed in the table are the most commonly used, stable and representative sensors in each temperature range. Consult the manufacturer for details of accuracy in a wider temperature range.
Note 2: The thermocouple matching function is a patented technology and must be completed before leaving the factory.
Note 3: The accuracy of thermocouples in the table includes the accuracy of cold junction compensation and does not need to be superimposed separately.

More products