JTR-6100 integrated field display temperature transmitter
Classification:
Keywords: JTR-6100 integrated field display temperature transmitter
E-mail:
Product Description
Input type: 2/3/4 wire PT100
Output mode: two-wire 4 ~ 20mA current ring 6-bit LCD segment code display with backlight
Output resolution: 1μuA
Data update rate: 0.5 seconds -2/4 wire PT100 1 seconds -3 wire PT100
Operating environment:-35~85 ℃ 0 ~ 95% relative humidity
Flameproof grade: IICT6
Special function: can be matched with the sensor, to achieve ultra-high precision measurement.
Electrical isolation: non-isolated
Power supply: 8 ~ 36VDC
Accuracy (AT 25 ℃ maximum):
Enter model number | Range (℃) | A/D conversion accuracy | D/A conversion accuracy | Influence of 1 ℃ of environment change (temperature drift) |
PT100 | -200~500 | ±0.05℃ | ± 0.075% of range | 0.003 ℃ |
digital/analog conversion |
|
|
| 0.0025% Span |
Note 1: Total accuracy of transmitter: analog-to-digital conversion accuracy, digital-to-analog conversion accuracy, please refer to the previous "about accuracy" for calculation method"
Overall accuracy after using sensor matching function (transmitter sensor)
Enter model number | Range (℃) | Accuracy of analog/digital conversion (℃) |
PT100 | -50~200 | ±0.05 |
Note 1: The sensors listed in the table are the most commonly used, stable and representative sensors in each temperature range. Consult the manufacturer for details of accuracy in a wider temperature range.